Design switchgear plan as SLD (Single Line Drawing)
Product Introduction:
KYN61-40.5 Metal-enclosed switchgear 3P AC 50Hz, rated voltage of 40.5kV suitable for power plant, substation and power distribution to industrial and mining enterprises, railway transportation as the acceptance and distribution of electric energy. And the implementation of control, protection and monitoring function of circuit. The utility model has the advantages of flexible operation, reliable electrical performance, long service life, convenient maintenance. KNY61-60.5 can be equipped with ABB/Schneider/XC electric series 40.5KV VCB. Service environment: a) Air temperature: -25℃~+40℃ b) Humidity:Monthly average humidity 95%; Daily average humidity 90% . c) Altitude:≤ 2500m d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. e) No frequent violent shake Technical data Items Unit Data Rated Voltage KV 40.5 Rated Frequency Hz 50 Rated Current A 1250,1600,2000 Rated Short-circuit Breaking Current KA 25,31.5 Rated Making Current (Peak) KA 63,80 4s Thermal Stability Current KA 25,31.5 Rated Dynamic Current (Peak) KA 63,80 Rated Insulation Level 1min Power Frequency Withstand Voltage (r.m.s) KV 95 Lightning Impulse Withstand Voltage (Peak) KV 185 1min Power Frequency Voltage Across the open gap (r.m.s) KV 118 Lightning Impulse Withstand Voltage Across the open gap (Peak) KV 215 Enclosure Protection Class Enclosure IP4X, Between Compartments IP2X Enclosure Dimension (Width*Depth*Height) mm 1400*2800*2600 Type of Circuit Breaker VCB:ZN85-40.5 *Note: order switchgear should provide SLD(Single-line diagram) by customer Main components charateristics: VS1-40.5 Indoor Vacuum Circuit Breaker Rated voltage: 40.5kV Rated current: 630 1250 1600 2000 2500A Rated short circuit breaking current: 20 25 31.5KA Mechanical life: 20,000 times VS1-40.5 Technical data Items Unit Date Rated voltage KV 40.5 Rated short-time power frequency withstand voltage (1min) 95 Rated lightning impulse withstand voltage (peak) 185 Rated freq Hz 50/60 Rated current A 1250 1600 2000 2500 4000 Rated short-circuit drop-out current KA 25 31.5 Rated short time withstand current 25 31.5 Rated short time continual time s 4 Rated peak withstand current KA 63 80 Rated short-circuit closing current 63 80 Rated single/ back-to-back capacitor bank drop-out current A 630/400 Opening time (rated volt.) ms 35~60 Closing time (rated volt.) 50~100 Mechanical life times 20000 Rated break times for rated short drop out current s 20 Rated operation voltage V AC110/220 DC110/220 Rated current of power storing motor W 230 Average opening speed m/s 1.6~2.0 Average closing speed 0.5~0.8 Rated operation procedure opening-0.3s-closing opening-180s-closing opening Appreciate for the hard work of our professional electrical engineering team, the international evaluation of our 33kv switchgear is positive. Fully type-tested The switchgear has undergone all the tests required by the international (IEC) Standards. Each switchgear unit is subjected to routine tests in the factory before delivery. These tests are intended to provide a functional check of the switchgear based on the specific characteristics of each installation. IEC type tests • Short-time and peak withstand current • Temperature rise • Internal arc capability • Dielectric test • Making and breaking capacity of circuit-breaker • Earthing switch making capacity (top application) • Mechanical operations of circuit-breaker and line disconnector • IP degree and impact test IEC routine factory tests • Visual inspection and check • Mechanical sequence operations • Cabling check • Electrical sequence operations • Power frequency withstand voltage • Measurement of the resistance of the main circuits • Secondary insulation test
1600*2800*2600
SF6 Circuit Breaker
XC Electric 33KV switchgear has served the international market over 10 years.